Close

LABType® XR and CWD  

LABType XR and CWD assays are built on the 500 bead regions available exclusively for use with the LABScan3D™. Extended exon coverage for these assays and the ability to multiplex up to 500 bead regions allows for higher resolution.

The CWD assays are designed to resolve alleles as defined by the CWD catalog and the XR assays are designed for laboratories interested in increased resolution beyond the CWD assay.

Sales Contact

Service Contact

Contact Us About This Product

Product Description

Read More..

FEATURES & BENEFITS

  • 500 bead multiplexing
  • Locus and Exon Coverage:
    • A locus: Exons 2-5
    • B locus: Exons 2-5
    • C locus: Exons 2-7
    • DRB1 locus: Exon 2

 

Related Product & News

LABScan3D™ ❯

 

LABType Reagent List ❯

 

 

Regulatory

Regulatory status and intended use vary by catalog number. Refer to individual product specifications.

Please select either a Category and/or a Product Line before searching for documents.

No results found for current filter selection

Refine By:

  • Product Documents

No Results found.

 Results found for 

Notice: Download functionality is optimized for IE 10 and above. Downloads are limited to 50 documents at a time.

tab 4

Showing 10 32 of 32 Products
Catalog #
Product Name
Target
Format
Amount
RSSOX1AR
LABType XR Class I A Locus Typing Test
HLA-A
XR
100 tests
Full Specification
HLA Class I
Product Name LABType XR Class I A Locus Typing Test
Format XR
Regulatory For Research Use Only. Not for use in diagnostic procedures.
Use DNA typing of Class I HLA-A alleles
Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
Shipping Considerations Cold Pack
Storage Temperature -80° to -20° C
Amount 100 tests
Target HLA-A

Error adding product to cart

    Please wait, while adding to cart

    Invalid Catalog Number, try after few minutes

    Unable to connect to commerce server, try after few minutes

    RSOX1ATR
    LABType XR Class I A Locus Typing Test
    HLA-A
    XR
    20 test
    Full Specification
    HLA Class I
    Product Name LABType XR Class I A Locus Typing Test
    Format XR
    Regulatory For Research Use Only. Not for use in diagnostic procedures.
    Use DNA typing of Class I HLA-A alleles
    Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
    Shipping Considerations Cold Pack
    Storage Temperature -80° to -20° C
    Amount 20 test
    Target HLA-A

    Error adding product to cart

      Please wait, while adding to cart

      Invalid Catalog Number, try after few minutes

      Unable to connect to commerce server, try after few minutes

      RSSOX1A
      LABType XR Class I A Locus Typing Test
      HLA-A
      XR
      100 tests
      Full Specification
      HLA Class I
      Product Name LABType XR Class I A Locus Typing Test
      Format XR
      Regulatory For In Vitro Diagnostic Use.
      Use DNA typing of Class I HLA-A alleles
      Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
      Shipping Considerations Cold Pack
      Storage Temperature -80° to -20° C
      Amount 100 tests
      Target HLA-A

      Error adding product to cart

        Please wait, while adding to cart

        Invalid Catalog Number, try after few minutes

        Unable to connect to commerce server, try after few minutes

        RSOX1AT
        LABType XR Class I A Locus Typing Test
        HLA-A
        XR
        20 tests
        Full Specification
        HLA Class I
        Product Name LABType XR Class I A Locus Typing Test
        Format XR
        Regulatory For In Vitro Diagnostic Use.
        Use DNA typing of Class I HLA-A alleles
        Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
        Shipping Considerations Cold Pack
        Storage Temperature -80° to -20° C
        Amount 20 tests
        Target HLA-A

        Error adding product to cart

          Please wait, while adding to cart

          Invalid Catalog Number, try after few minutes

          Unable to connect to commerce server, try after few minutes

          RSSOW1AR
          LABType CWD Class I A Locus Typing Test
          HLA-A
          CWD
          100 tests
          Full Specification
          HLA Class I
          Product Name LABType CWD Class I A Locus Typing Test
          Format CWD
          Regulatory For Research Use Only. Not for use in diagnostic procedures.
          Use DNA typing of Class I HLA-A alleles
          Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
          Shipping Considerations Cold Pack
          Storage Temperature -80° to -20° C
          Amount 100 tests
          Target HLA-A

          Error adding product to cart

            Please wait, while adding to cart

            Invalid Catalog Number, try after few minutes

            Unable to connect to commerce server, try after few minutes

            RSOW1ATR
            LABType CWD Class I A Locus Typing Test
            HLA-A
            CWD
            20 test
            Full Specification
            HLA Class I
            Product Name LABType CWD Class I A Locus Typing Test
            Format CWD
            Regulatory For Research Use Only. Not for use in diagnostic procedures.
            Use DNA typing of Class I HLA-A alleles
            Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
            Shipping Considerations Cold Pack
            Storage Temperature -80° to -20° C
            Amount 20 test
            Target HLA-A

            Error adding product to cart

              Please wait, while adding to cart

              Invalid Catalog Number, try after few minutes

              Unable to connect to commerce server, try after few minutes

              RSSOW1A
              LABType CWD Class I A Locus Typing Test
              HLA-A
              CWD
              100 tests
              Full Specification
              HLA Class I
              Product Name LABType CWD Class I A Locus Typing Test
              Format CWD
              Regulatory For In Vitro Diagnostic Use.
              Use DNA typing of Class I HLA-A alleles
              Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
              Shipping Considerations Cold Pack
              Storage Temperature -80° to -20° C
              Amount 100 tests
              Target HLA-A

              Error adding product to cart

                Please wait, while adding to cart

                Invalid Catalog Number, try after few minutes

                Unable to connect to commerce server, try after few minutes

                RSOW1AT
                LABType CWD Class I A Locus Typing Test
                HLA-A
                CWD
                20 tests
                Full Specification
                HLA Class I
                Product Name LABType CWD Class I A Locus Typing Test
                Format CWD
                Regulatory For In Vitro Diagnostic Use.
                Use DNA typing of Class I HLA-A alleles
                Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                Shipping Considerations Cold Pack
                Storage Temperature -80° to -20° C
                Amount 20 tests
                Target HLA-A

                Error adding product to cart

                  Please wait, while adding to cart

                  Invalid Catalog Number, try after few minutes

                  Unable to connect to commerce server, try after few minutes

                  RSSOX1BR
                  LABType XR Class I B Locus Typing Test
                  HLA-B
                  XR
                  100 tests
                  Full Specification
                  HLA Class I
                  Product Name LABType XR Class I B Locus Typing Test
                  Format XR
                  Regulatory For Research Use Only. Not for use in diagnostic procedures.
                  Use DNA typing of Class I HLA-B alleles
                  Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                  Shipping Considerations Cold Pack
                  Storage Temperature -80° to -20° C
                  Amount 100 tests
                  Target HLA-B

                  Error adding product to cart

                    Please wait, while adding to cart

                    Invalid Catalog Number, try after few minutes

                    Unable to connect to commerce server, try after few minutes

                    RSOX1BTR
                    LABType XR Class I B Locus Typing Test
                    HLA-B
                    XR
                    20 test
                    Full Specification
                    HLA Class I
                    Product Name LABType XR Class I B Locus Typing Test
                    Format XR
                    Regulatory For Research Use Only. Not for use in diagnostic procedures.
                    Use DNA typing of Class I HLA-B alleles
                    Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                    Shipping Considerations Cold Pack
                    Storage Temperature -80° to -20° C
                    Amount 20 test
                    Target HLA-B

                    Error adding product to cart

                      Please wait, while adding to cart

                      Invalid Catalog Number, try after few minutes

                      Unable to connect to commerce server, try after few minutes

                      RSSOX1B
                      LABType XR Class I B Locus Typing Test
                      HLA-B
                      XR
                      100 tests
                      Full Specification
                      HLA Class I
                      Product Name LABType XR Class I B Locus Typing Test
                      Format XR
                      Regulatory For In Vitro Diagnostic Use.
                      Use DNA typing of Class I HLA-B alleles
                      Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                      Shipping Considerations Cold Pack
                      Storage Temperature -80° to -20° C
                      Amount 100 tests
                      Target HLA-B

                      Error adding product to cart

                        Please wait, while adding to cart

                        Invalid Catalog Number, try after few minutes

                        Unable to connect to commerce server, try after few minutes

                        RSOX1BT
                        LABType XR Class I B Locus Typing Test
                        HLA-B
                        XR
                        20 tests
                        Full Specification
                        HLA Class I
                        Product Name LABType XR Class I B Locus Typing Test
                        Format XR
                        Regulatory For In Vitro Diagnostic Use.
                        Use DNA typing of Class I HLA-B alleles
                        Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                        Shipping Considerations Cold Pack
                        Storage Temperature -80° to -20° C
                        Amount 20 tests
                        Target HLA-B

                        Error adding product to cart

                          Please wait, while adding to cart

                          Invalid Catalog Number, try after few minutes

                          Unable to connect to commerce server, try after few minutes

                          RSSOW1BR
                          LABType CWD Class I B Locus Typing Test
                          HLA-B
                          CWD
                          100 tests
                          Full Specification
                          HLA Class I
                          Product Name LABType CWD Class I B Locus Typing Test
                          Format CWD
                          Regulatory For Research Use Only. Not for use in diagnostic procedures.
                          Use DNA typing of Class I HLA-B alleles
                          Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                          Shipping Considerations Cold Pack
                          Storage Temperature -80° to -20° C
                          Amount 100 tests
                          Target HLA-B

                          Error adding product to cart

                            Please wait, while adding to cart

                            Invalid Catalog Number, try after few minutes

                            Unable to connect to commerce server, try after few minutes

                            RSOW1BTR
                            LABType CWD Class I B Locus Typing Test
                            HLA-B
                            CWD
                            20 test
                            Full Specification
                            HLA Class I
                            Product Name LABType CWD Class I B Locus Typing Test
                            Format CWD
                            Regulatory For Research Use Only. Not for use in diagnostic procedures.
                            Use DNA typing of Class I HLA-B alleles
                            Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                            Shipping Considerations Cold Pack
                            Storage Temperature -80° to -20° C
                            Amount 20 test
                            Target HLA-B

                            Error adding product to cart

                              Please wait, while adding to cart

                              Invalid Catalog Number, try after few minutes

                              Unable to connect to commerce server, try after few minutes

                              RSSOW1B
                              LABType CWD Class I B Locus Typing Test
                              HLA-B
                              CWD
                              100 tests
                              Full Specification
                              HLA Class I
                              Product Name LABType CWD Class I B Locus Typing Test
                              Format CWD
                              Regulatory For In Vitro Diagnostic Use.
                              Use DNA typing of Class I HLA-B alleles
                              Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                              Shipping Considerations Cold Pack
                              Storage Temperature -80° to -20° C
                              Amount 100 tests
                              Target HLA-B

                              Error adding product to cart

                                Please wait, while adding to cart

                                Invalid Catalog Number, try after few minutes

                                Unable to connect to commerce server, try after few minutes

                                RSOW1BT
                                LABType CWD Class I B Locus Typing Test
                                HLA-B
                                CWD
                                20 Tests
                                Full Specification
                                HLA Class I
                                Product Name LABType CWD Class I B Locus Typing Test
                                Format CWD
                                Regulatory For In Vitro Diagnostic Use.
                                Use DNA typing of Class I HLA-B alleles
                                Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                Shipping Considerations Cold Pack
                                Storage Temperature -80° to -20° C
                                Amount 20 Tests
                                Target HLA-B

                                Error adding product to cart

                                  Please wait, while adding to cart

                                  Invalid Catalog Number, try after few minutes

                                  Unable to connect to commerce server, try after few minutes

                                  RSSOX1CR
                                  LABType XR Class I C Locus Typing Test
                                  HLA-C
                                  XR
                                  100 tests
                                  Full Specification
                                  HLA Class I
                                  Product Name LABType XR Class I C Locus Typing Test
                                  Format XR
                                  Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                  Use DNA typing of Class I HLA-C alleles
                                  Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                  Shipping Considerations Cold Pack
                                  Storage Temperature -80° to -20° C
                                  Amount 100 tests
                                  Target HLA-C

                                  Error adding product to cart

                                    Please wait, while adding to cart

                                    Invalid Catalog Number, try after few minutes

                                    Unable to connect to commerce server, try after few minutes

                                    RSOX1CTR
                                    LABType XR Class I C Locus Typing Test
                                    HLA-C
                                    XR
                                    20 test
                                    Full Specification
                                    HLA Class I
                                    Product Name LABType XR Class I C Locus Typing Test
                                    Format XR
                                    Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                    Use DNA typing of Class I HLA-C alleles
                                    Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                    Shipping Considerations Cold Pack
                                    Storage Temperature -80° to -20° C
                                    Amount 20 test
                                    Target HLA-C

                                    Error adding product to cart

                                      Please wait, while adding to cart

                                      Invalid Catalog Number, try after few minutes

                                      Unable to connect to commerce server, try after few minutes

                                      RSSOX1C
                                      LABType XR Class I C Locus Typing Test
                                      HLA-C
                                      XR
                                      100 tests
                                      Full Specification
                                      HLA Class I
                                      Product Name LABType XR Class I C Locus Typing Test
                                      Format XR
                                      Regulatory CE/IVD: For In Vitro Diagnostic Use. (European Union Only)
                                      Use DNA typing of HLA Class I HLA-C alleles.
                                      Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                      Shipping Considerations Cold Pack
                                      Storage Temperature -80° to -20° C
                                      Amount 100 tests
                                      Target HLA-C

                                      Error adding product to cart

                                        Please wait, while adding to cart

                                        Invalid Catalog Number, try after few minutes

                                        Unable to connect to commerce server, try after few minutes

                                        RSOX1CT
                                        LABType XR Class I C Locus Typing Test
                                        HLA-C
                                        XR
                                        20 tests
                                        Full Specification
                                        HLA Class I
                                        Product Name LABType XR Class I C Locus Typing Test
                                        Format XR
                                        Regulatory CE/IVD: For In Vitro Diagnostic Use. (European Union Only)
                                        Use DNA typing of HLA Class I HLA-C alleles.
                                        Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                        Shipping Considerations Cold Pack
                                        Storage Temperature -80° to -20° C
                                        Amount 20 tests
                                        Target HLA-C

                                        Error adding product to cart

                                          Please wait, while adding to cart

                                          Invalid Catalog Number, try after few minutes

                                          Unable to connect to commerce server, try after few minutes

                                          RSSOW1CR
                                          LABType CWD Class I C Locus Typing Test
                                          HLA-C
                                          CWD
                                          100 tests
                                          Full Specification
                                          HLA Class I
                                          Product Name LABType CWD Class I C Locus Typing Test
                                          Format CWD
                                          Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                          Use DNA typing of HLA Class I HLA-C alleles
                                          Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                          Shipping Considerations Cold Pack
                                          Storage Temperature -80° to -20° C
                                          Amount 100 tests
                                          Target HLA-C

                                          Error adding product to cart

                                            Please wait, while adding to cart

                                            Invalid Catalog Number, try after few minutes

                                            Unable to connect to commerce server, try after few minutes

                                            RSOW1CTR
                                            LABType CWD Class I C Locus Typing Test
                                            HLA-C
                                            CWD
                                            20 tests
                                            Full Specification
                                            HLA Class I
                                            Product Name LABType CWD Class I C Locus Typing Test
                                            Format CWD
                                            Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                            Use DNA typing of HLA Class I HLA-C alleles
                                            Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                            Shipping Considerations Cold Pack
                                            Storage Temperature -80° to -20° C
                                            Amount 20 tests
                                            Target HLA-C

                                            Error adding product to cart

                                              Please wait, while adding to cart

                                              Invalid Catalog Number, try after few minutes

                                              Unable to connect to commerce server, try after few minutes

                                              RSSOW1C
                                              LABType CWD Class I C Locus Typing Test
                                              HLA-C
                                              CWD
                                              100 tests
                                              Full Specification
                                              HLA Class I
                                              Product Name LABType CWD Class I C Locus Typing Test
                                              Format CWD
                                              Regulatory CE/IVD: For In Vitro Diagnostic Use. (European Union Only)
                                              Use DNA typing of HLA Class I HLA-C alleles.
                                              Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                              Shipping Considerations Cold Pack
                                              Storage Temperature -80° to -20° C
                                              Amount 100 tests
                                              Target HLA-C

                                              Error adding product to cart

                                                Please wait, while adding to cart

                                                Invalid Catalog Number, try after few minutes

                                                Unable to connect to commerce server, try after few minutes

                                                RSOW1CT
                                                LABType CWD Class I C Locus Typing Test
                                                HLA-C
                                                CWD
                                                20 tests
                                                Full Specification
                                                HLA Class I
                                                Product Name LABType CWD Class I C Locus Typing Test
                                                Format CWD
                                                Regulatory CE/IVD: For In Vitro Diagnostic Use. (European Union Only)
                                                Use DNA typing of HLA Class I HLA-C alleles.
                                                Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                Shipping Considerations Cold Pack
                                                Storage Temperature -80° to -20° C
                                                Amount 20 tests
                                                Target HLA-C

                                                Error adding product to cart

                                                  Please wait, while adding to cart

                                                  Invalid Catalog Number, try after few minutes

                                                  Unable to connect to commerce server, try after few minutes

                                                  RSSOX2B1R
                                                  LABType XR Class II DRB1 Locus Typing Test
                                                  HLA-DRB
                                                  XR
                                                  100 tests
                                                  Full Specification
                                                  HLA Class II
                                                  Product Name LABType XR Class II DRB1 Locus Typing Test
                                                  Format XR
                                                  Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                                  Use DNA typing of Class II HLA-DRB1 alleles
                                                  Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                  Shipping Considerations Cold Pack
                                                  Storage Temperature -80° to -20° C
                                                  Amount 100 tests
                                                  Target HLA-DRB

                                                  Error adding product to cart

                                                    Please wait, while adding to cart

                                                    Invalid Catalog Number, try after few minutes

                                                    Unable to connect to commerce server, try after few minutes

                                                    RSOX2B1TR
                                                    LABType XR Class II DRB1 Locus Typing Test
                                                    HLA-DRB
                                                    XR
                                                    20 test
                                                    Full Specification
                                                    HLA Class II
                                                    Product Name LABType XR Class II DRB1 Locus Typing Test
                                                    Format XR
                                                    Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                                    Use DNA typing of Class II HLA-DRB1 alleles
                                                    Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                    Shipping Considerations Cold Pack
                                                    Storage Temperature -80° to -20° C
                                                    Amount 20 test
                                                    Target HLA-DRB

                                                    Error adding product to cart

                                                      Please wait, while adding to cart

                                                      Invalid Catalog Number, try after few minutes

                                                      Unable to connect to commerce server, try after few minutes

                                                      RSSOX2B1
                                                      LABType XR Class II DRB1 Locus Typing Test
                                                      HLA-DRB
                                                      XR
                                                      100 tests
                                                      Full Specification
                                                      HLA Class II
                                                      Product Name LABType XR Class II DRB1 Locus Typing Test
                                                      Format XR
                                                      Regulatory For In Vitro Diagnostic Use.
                                                      Use DNA typing of Class II HLA-DRB1 alleles
                                                      Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                      Shipping Considerations Cold pack
                                                      Storage Temperature -80° to -20° C
                                                      Amount 100 tests
                                                      Target HLA-DRB

                                                      Error adding product to cart

                                                        Please wait, while adding to cart

                                                        Invalid Catalog Number, try after few minutes

                                                        Unable to connect to commerce server, try after few minutes

                                                        RSOX2B1T
                                                        LABType XR Class II DRB1 Locus Typing Test
                                                        HLA-DRB
                                                        XR
                                                        20 Tests
                                                        Full Specification
                                                        HLA Class II
                                                        Product Name LABType XR Class II DRB1 Locus Typing Test
                                                        Format XR
                                                        Regulatory For In Vitro Diagnostic Use.
                                                        Use DNA typing of Class II HLA-DRB1 alleles
                                                        Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                        Shipping Considerations Cold Pack
                                                        Storage Temperature -80° to -20° C
                                                        Amount 20 Tests
                                                        Target HLA-DRB

                                                        Error adding product to cart

                                                          Please wait, while adding to cart

                                                          Invalid Catalog Number, try after few minutes

                                                          Unable to connect to commerce server, try after few minutes

                                                          RSSOW2B1R
                                                          LABType CWD Class II DRB1 Locus Typing Test
                                                          HLA-DRB
                                                          CWD
                                                          100 tests
                                                          Full Specification
                                                          HLA Class II
                                                          Product Name LABType CWD Class II DRB1 Locus Typing Test
                                                          Format CWD
                                                          Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                                          Use DNA typing of Class II HLA-DRB1 alleles
                                                          Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                          Shipping Considerations Cold Pack
                                                          Storage Temperature -80° to -20° C
                                                          Amount 100 tests
                                                          Target HLA-DRB

                                                          Error adding product to cart

                                                            Please wait, while adding to cart

                                                            Invalid Catalog Number, try after few minutes

                                                            Unable to connect to commerce server, try after few minutes

                                                            RSOW2B1TR
                                                            LABType CWD Class II DRB1 Locus Typing Test
                                                            HLA-DRB
                                                            CWD
                                                            20 test
                                                            Full Specification
                                                            HLA Class II
                                                            Product Name LABType CWD Class II DRB1 Locus Typing Test
                                                            Format CWD
                                                            Regulatory For Research Use Only. Not for use in diagnostic procedures.
                                                            Use DNA typing of Class II HLA-DRB1 alleles
                                                            Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                            Shipping Considerations Cold Pack
                                                            Storage Temperature -80° to -20° C
                                                            Amount 20 test
                                                            Target HLA-DRB

                                                            Error adding product to cart

                                                              Please wait, while adding to cart

                                                              Invalid Catalog Number, try after few minutes

                                                              Unable to connect to commerce server, try after few minutes

                                                              RSSOW2B1
                                                              LABType CWD Class II DRB1 Locus Typing Test
                                                              HLA-DRB
                                                              CWD
                                                              100 tests
                                                              Full Specification
                                                              HLA Class II
                                                              Product Name LABType CWD Class II DRB1 Locus Typing Test
                                                              Format CWD
                                                              Regulatory For In Vitro Diagnostic Use.
                                                              Use DNA typing of Class II HLA-DRB1 alleles
                                                              Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                              Shipping Considerations Cold Pack
                                                              Storage Temperature -80° to -20° C
                                                              Amount 100 tests
                                                              Target HLA-DRB

                                                              Error adding product to cart

                                                                Please wait, while adding to cart

                                                                Invalid Catalog Number, try after few minutes

                                                                Unable to connect to commerce server, try after few minutes

                                                                RSOW2B1T
                                                                LABType CWD Class II DRB1 Locus Typing Test
                                                                HLA-DRB
                                                                CWD
                                                                20 Tests
                                                                Full Specification
                                                                HLA Class II
                                                                Product Name LABType CWD Class II DRB1 Locus Typing Test
                                                                Format CWD
                                                                Regulatory For In Vitro Diagnostic Use.
                                                                Use DNA typing of Class II HLA-DRB1 alleles
                                                                Package Includes LABType Bead Mix, Locus Specific Primer Set, Primer Set D-Mix, Denaturation Buffer, Neutralization Buffer, Hybridization Buffer, SAPE Buffer, Wash Buffer
                                                                Shipping Considerations Cold Pack
                                                                Storage Temperature -80° to -20° C
                                                                Amount 20 Tests
                                                                Target HLA-DRB

                                                                Error adding product to cart

                                                                  Please wait, while adding to cart

                                                                  Invalid Catalog Number, try after few minutes

                                                                  Unable to connect to commerce server, try after few minutes